3. Enter the new value. Select the enter key.

If your system includes the optional relay module (K1), the following function numbers are used
for setup. Before these functions can be programmed, the monitor must be in program mode.
To put the monitor in program mode, see Program Mode Access in Section 4.7: Program and
Supervisory Mode Functions. The following is a list of the press setup functions.

• Upper End Limit (400)

• Lower End Limit (401)

• Relay State (402)

• Relay Override (403)

Upper End Limit (400)

The Upper End Limit function is used to program the upper limit of the shut height opening.
This can prevent the ram from accidentally exceeding its mechanical adjustment capabilities.
If the shut height reaches or exceeds the value programmed in this function, the upper limit
relay will de-energize and the upper limit LED will turn on. This can cause power to be taken
away from the press’s ram adjust motor(s) if the upper limit relay is properly wired. (For wiring
instructions, see Section 3.2: Wiring.) The default for this function is 999.999 inches. This
value can range from 0 to 999.999 inches. To program a value for the Upper End Limit function,
perform the following steps:

1. Select the function key.

The monitor displays “F-----”

2. Enter function number 400. Select the enter key.

The monitor displays the function’s current value.

3. Enter the new value. Select the enter key.

NOTE: To temporarily regain lost power to the ram adjust motor(s) (close the upper end limit

relay) if the shut height reaches or exceeds the upper end limit, see Relay Override.

Enter new
setting

400

Enter upper
limit

4.4: Relay Setup Functions - Option K1

(F)

8

8

8