Press setup functions – AMETEK 2110 Shut Height Monitor User Manual

Page 41

Advertising
background image

Installation and Programming Manual

36

Chapter 4: Programming

37

Installation and Programming Manual

Chapter 4: Programming

This section provides descriptions and instructions for press setup functions. These functions
provide the means to customize the press’s setup for a specific installation. Before these
functions can be programmed, the monitor must be in program mode. To put the monitor in
program mode, see Program Mode Access in Section 4.6: Program and Supervisory Mode
Functions. The following is a list of the press setup functions:

n Move Detection Time-Out (12)

n Bolster Offset (303)

n Negative Over Travel Limit (304)

n Upper End Limit (400)

n Lower End Limit (401)

n Relay State (402)

n Relay Override (403)

Move Detection Time-out (12)

The Move Detection Time-out function is used to program the time the press’s shut height
must move within when power is applied to the ram adjust motor(s). The default value for this
function is 5.00 seconds. This value can range from 0 to 99.99 seconds. Entering a 0 disables
this function. The purpose of this function is to detect a possible jam or drive component failure.
When power is applied to the press’s ram adjust motor(s), the monitor’s auxiliary input receives
an AC voltage. When this occurs, the monitor begins to look for shut height movement. If
movement is not detected within the programmed time, the upper and lower limit relays will
de-energize and the fault check relay will open. Also, the movement fault LED will turn on and
the monitor will display an error message (see Appendix A: Error Messages). This error will
have to be cleared before machine operation can resume. To change the move detection time-out
value or disable the function, perform the following steps:

1. Select the function key.

The monitor displays “F-----”

2. Enter function number 12. Select the enter key.

The monitor displays the function’s current value.

3. Enter the new time-out value. Select the enter key.

12

Enter new
time-out
value

4.4: Press Setup Functions

(F)

8

8

T13692 Chapter 4.indd

3/17/04, 6:50 AM

37

Advertising