AMETEK 2110 Shut Height Monitor User Manual

Page 55

Advertising
background image

Installation and Programming Manual

50

Appendix A: Error Messages

51

Installation and Programming Manual

Appendix A: Error Messages

The following charts contain descriptions and solutions for the three types of errors that can appear
on the monitor’s LED display. To clear errors, perform the solutions found in charts A-1, A-2, and
A-3, followed by pressing either the scroll, shift, or enter.

Chart A-1 System Errors

Chart A-2 Operating Errors

Error Displayed

Error Description

Solution

SEr101

A configuration error has occurred.

Contact GEMCO Tech. Support.

SEr102

The monitor's function parameter
memory has been corrupted.

Contact GEMCO Tech. Support.

SEr103

The battery for the monitor's memo-
ry is low.

Contact GEMCO Tech. Support.

SEr104

A software fault has occurred.

Contact GEMCO Tech. Support.

SEr105

An error has occurred with the
monitor's internal memory locations.

Clear the error and contact GEMCO
Tech. Support.

SEr106

A firmware CRC error has occurred. Contact GEMCO Tech. Support.

SEr320

This is a resolver-specific error. See
Chart A-6.

SEr330

The input device is not connected to
the monitor's input module.

Connect the input device to the
input module and clear the error.

SEr331

This is an LDT-specific error. See
Chart A-7.

Error Displayed

Error Description

Solution

OEr101

The press's ram did not move within
the time programmed in the Move
Detection Time-Out function.

Review press operation and/or in-
crease the value of the Move Detec-
tion Time-Out function.

OER330 or
OEr320

The press's shut height moved be-
yond the value programmed in the
Negative Over Travel Limit Func-
tion.

Review press operation and/or
increase the value of the negative
Over Travel Limit function.

T13692 appendix a.indd

3/17/04, 6:54 AM

51

Advertising