Appendix A: Error Messages

53

Installation and Programming Manual

Appendix A: Error Messages

The following errors will cause the upper and lower limit relays to de-energize:

Chart A-5 Upper and Lower Limit Relay Errors

The following chart contains a resolver-specific error:

Chart A-6 Resolver-Specific Error

Error Displayed

Error Description

SEr320

This is a resolver-specific error. See Chart A-6.

SEr330

The input device is not connected to the monitor's input module.

SEr331

This is a LDT-specific error. See Chart A-7.

OEr101

The press's ram did not move within the time programmed in the Move
Detection Time-Out function.

OEr330 or
OEr320

The press's shut height moved beyond the value programmed in the Nega-
tive Over Travel Limit functions.

Error Displayed

Error Description

Solution

SEr320

The cable may not be connected, an
open or short may exist in the cable,
or the resolver's primary may be
open or shorted.

To determine the exact condition,
enter the Error Conditions function
(306). For instructions, see Error
Conditions (306) following this
chart.