2 sensor mounting brackets, 1 crossarm mounting, 1 cm202, cm203, cm204, cm206 crossarms – Campbell Scientific UT10 10 foot Tower w/ Grounding Kit and Hinged Base User Manual

Page 22: Sensor mounting brackets, Crossarm mounting, Cm202, cm203, cm204, cm206 crossarms, 6. ut10 mounting foot detail view

Advertising
background image

UT10 Weather Station

FIGURE 7-6. UT10 Mounting Foot Detail View

6. Check the UT10 for plumb using a level and adjust the leveling nuts below

the mounting feet on the J-bolts as required. When the tower is plumb, use

two wrenches to lock the lower nuts on each J-bolt together. Tighten the

upper nuts to secure the base.

7. Removing the lower 3/8 inch bolt on the rear (West) leg allows the tower

to be hinged to the ground. If a step ladder is available, it is easier to leave

the tower upright.

7.2 Sensor Mounting Brackets

Sensor mounting brackets provide a means of mounting the sensors to the

tower. General orientation of the mounting brackets is shown in FIGURE 7-7.

7.2.1 Crossarm Mounting

7.2.1.1 CM202, CM203, CM204, CM206 Crossarms

1. Attach the crossarm at the desired height via the provided U-bolts and nuts

(FIGURE 7-8).