5 sensor installation, 1 034b met one windset, Sensor installation – Campbell Scientific UT10 10 foot Tower w/ Grounding Kit and Hinged Base User Manual

Page 41: 034b met one windset, 12. enclosure supply kit

Advertising
background image

UT10 Weather Station

turn pink. The indicator card does not need to be replaced unless the

colored circles overrun.

FIGURE 8-12. Enclosure Supply Kit

8.5 Sensor Installation

Sensor leads should be routed down the North side of the mast to the enclosure

and secured with cable ties.

8.5.1 034B Met One Windset

Mount the 034B to the CM202, CM204, or CM206 crossarm as shown in

FIGURE 8-13.

1. Mount the CM220 bracket on the crossarm via the U-bolt and nuts.

2. Place the 034B stem and bushing into the CM220 bracket.

3. With the shoulder screw in place, orient the counter weight to point due

south. See Section 8.5.17, Wind Direction Sensor Orientation, for final

calibration.

4. Tighten the CM220’s U-bolt and nuts and remove the shoulder screw.

31