2 019alu crossarm, 019alu crossarm, 7. top view of tower – Campbell Scientific UT10 10 foot Tower w/ Grounding Kit and Hinged Base User Manual

Page 23

Advertising
background image

UT10 Weather Station

7.2.1.2 019ALU Crossarm

Attach the 019ALU crossarm to the mast as shown in FIGURE 7-9.

2. Position the middle NU-RAIL so that it rests on top of the bell reducer.

Orient the 019ALU in an East/West direction, with the 3/4 inch NU-RAIL

facing East and tighten the set screws. If the 019ALU is used with the 025

Crossarm Stand, orient the 019ALU North/South, with the 3/4 inch NU-

RAIL facing South.

3. Install the lightning rod to the mast as shown in FIGURE 7-9. Loosen the

two screws on the lightning rod mounting bracket. Position the mounting

bracket 2 in down from the top of the mast and tighten both screws evenly.

Make sure the lightning rod set screw is tight.

7.2.2 Gill Radiation Shields (41303-5A, 41003-5, 41005-5)

1. Attach the radiation shield to the tower leg, tower mast, or CM202,

CM203, CM204, or CM206 crossarm with the U-bolt and nuts provided.

If attaching to the tower leg or mast, place U-bolt in the radiation shield’s

side holes. If attaching to a crossarm, place the U-bolt in the radiation

shield’s bottom holes.

FIGURE 7-7. Top View of Tower

North

13