3 03002 rm young wind sentry wind set, 1 03002 mounted to the mast, 2 03002 mounted to cm202, cm204, or cm206 crossarm – Campbell Scientific UT10 10 foot Tower w/ Grounding Kit and Hinged Base User Manual

Page 43: 03002 rm young wind sentry wind set, 03002 mounted to the mast, 03002 mounted to cm202, cm204, or cm206, Crossarm, 14. 05103 rm young wind monitor

Advertising
background image

UT10 Weather Station

FIGURE 8-14. 05103 RM Young Wind Monitor

8.5.3 03002 RM Young Wind Sentry Wind Set

The 03002 can be mounted directly to the mast, or to the CM202, CM204, or

CM206 Crossarm.

8.5.3.1 03002 Mounted to the Mast

1. Slide the crossarm mounting bracket onto the mast. Orient the crossarm so

the vane end points north, and tighten the band clamp (see Section 8.5.17,

Wind Direction Sensor Orientation, for final calibration).

2. Attach the cup assembly to the anemometer shaft using the Allen wrench

provided.

8.5.3.2 03002 Mounted to CM202, CM204, or CM206 Crossarm

Mount the 03002 to the crossarm as shown in FIGURE 8-15.

1. Attach the CM220 bracket on the crossarm via the U-bolt and nuts.

2. Position the top of the mounting post 5 in above the CM220 bracket and

tighten the set screws.

3. Slide the crossarm mounting bracket onto the mounting post. Orient the

crossarm so the vane end points north, and tighten the band clamp (see

Section 8.5.17, Wind Direction Sensor Orientation, for final calibration).

4. Attach the cup assembly to the anemometer shaft using the Allen wrench

provided.