FIGURE 8-15. 03002 Mounted to a CM200-series Crossarm

8.5.4 Licor Silicon Radiation Sensors (LI200X, LI200S, LI190SB)

Mount the Radiation Sensor to the LI2003S Base and Leveling Fixture as

shown in FIGURE 8-16.

1. Position the base of the sensor in the mounting flange on the LI2003S, and

tighten the set screw with the Allen wrench provided. Adjust the three

leveling screws flush with the bottom of the LI2003S.

2. Mount the LI2003S to the CM225 (Section 7.2, Sensor Mounting

Brackets) using the three mounting screws provided. Do not tighten the

screws at this time.

3. Level the LI2003S using the bubble level and leveling screws and tighten

the mounting screws.

Remove the red protective cap prior to use.

FIGURE 8-16. LI200X/LI200S/LI190SB and LI2003S Leveling Fixture

Bullseye

level
(3) Leveling

Screws

(3) Mounting

Screws

Sensor

CM225