UT10 Weather Station

FIGURE 8-13. Met One 034B Wind Speed and Direction Sensor

8.5.2 05103, 05103-45, 05106, and 05305 RM Young Wind Monitors

Mount the Wind Monitor to the CM202, CM204, or CM206 crossarm as

shown in FIGURE 8-14.

1. Attach the CM220 bracket on the crossarm via the U-bolt and nuts.

2. Position the top of the mounting post 5 in above the CM220 and tighten

the set screws.

3. Slide the orientation ring and the Wind Monitor onto the mounting post.

Rotate the sensor base so that the square wiring box points south. Engage

the key in the orientation ring with the keyway on the sensor and tighten

the band clamps (see Section 8.5.17, Wind Direction Sensor Orientation,

for final calibration).

4. Remove the plastic nut on the propeller shaft. Slide the propeller onto the

shaft (face the side with the lettering out) and replace the nut.