Product warranty – Goulds Pumps 3700 - IOM User Manual

Page 10

Advertising
background image

Introduction and Safety

If there are any questions regarding these requirements, the intended use, or if the equipment
requires modification, contact an ITT representative before you proceed.

Personnel requirements

ITT disclaims all responsibility for work done by untrained and unauthorized personnel.
These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:

• All work on the product must be carried out by certified electricians and ITT-authorized

mechanics. Special rules apply to installations in explosive atmospheres.

• All users must know about the risks of electric current and the chemical and physical

characteristics of the gas and/or vapor present in hazardous areas.

• Any maintenance for Ex-approved products must conform to international and national

standards (for example IEC/EN 60079-17).

Product and product handling requirements

These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:

• Only use the product in accordance with the approved motor data stated on the

nameplates.

• The Ex-approved product must never run dry during normal operation. Dry running during

service and inspection is only permitted outside the classified area.

• Never start a pump without the proper priming.

• Before you start working with the product, make sure that the product and the control panel

are isolated from the power supply and the control circuit, so they cannot be energized.

• Do not open the product while it is energized or in an explosive gas atmosphere.

• Make sure that thermal contacts are connected to a protection circuit according to the

approval classification of the product.

• Intrinsically safe circuits are normally required for the automatic level-control system by the

level regulator if mounted in zone 0.

• The yield stress of fasteners must be in accordance with the approval drawing and the

product specification.

• Do not modify the equipment without approval from an authorized ITT representative.

• Only use parts that have been provided by an authorized ITT representative.

Equipment for monitoring

For additional safety, use condition-monitoring devices. Condition-monitoring devices include
but are not limited to these devices:

• Pressure gauges

• Flow meters

• Level indicators

• Motor load readings

• Temperature detectors

• Bearing monitors

• Leak detectors

• PumpSmart control system

Product warranty

Coverage

ITT undertakes to remedy faults in products from ITT under these conditions:

• The faults are due to defects in design, materials, or workmanship.

8

Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance

Manual

Advertising