Goulds Pumps 3700 - IOM User Manual

Page 44

Advertising
background image

Commissioning, Startup, Operation, and Shutdown

a) Remove the spacer portion of the coupling.

Refer to the coupling manufacturer's instructions.

b) If the coupling hub diameter is larger than the diameter of the opening in the deflector-

fan guard support, then remove the coupling hub.

c) Loosen the thrust deflector-fan set screw.

122

Shaft

123B

Radial deflector fan

123E

Thrust deflector fan

222

Deflector set screw

228

Bearing frame

234

Thrust deflector-fan guard

234D

Thrust deflector-fan guard support

496Q

Support screws

d) Slide the thrust deflector fan off of the shaft.
e) Remove the thrust bearing end cover and the bearing frame screws.
f)

Align the thrust deflector-fan guard support with the thrust bearing end cover so that the
support slots align with the holes in the end cover.

g) Replace the thrust bearing end cover and bearing frame screws and torque to values

shown in the Maximum torque values for 3700 fasteners table.

CAUTION:
Do not over-tighten the thrust bearing end cover and bearing frame screws.

h) Install the thrust deflector fan over the shaft.
i)

Position the thrust deflector fan approximately 0.03 in. (0.8 mm) from the thrust bearing
end cover and firmly tighten the deflector set screw.

42

Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance

Manual

Advertising