Bearing lubrication, Oil volumes – Goulds Pumps 3700 - IOM User Manual

Page 48

Advertising
background image

Commissioning, Startup, Operation, and Shutdown

11. Slide the rear coupling guard half towards the motor so that it completely covers the shaft

and coupling.

1. Driver
2. Slide to fit

12. Repeat steps 5 through 7 for the center slots in the coupling guards.
13. Firmly tighten all of the nuts on the guard assembly.

Bearing lubrication

Precautions

WARNING:
Make sure to properly lubricate the bearings. Failure to do so can result in excess heat generation,
sparks, and premature failure.

NOTICE:
Avoid equipment damage. Refer to driver/coupling/gear manufactures IOM for instructions and
recommendations for lubrication.

Pumps are shipped without oil

You must lubricate oil-lubricated bearings at the job site.

Ring oil lubrication

Ring oil-lubricated bearings are standard. Bearing housings are supplied with constant-level
oilers and sight glasses. Make sure that oil rings are properly seated in the grooves in the shaft.

Pure or purge oil-mist lubrication

Pure or purge oil-mist are optional features for the 3700. Follow the oil-mist generator
manufacturer's instructions. The inlet and outlet connections are located on the top and bottom
of the bearing frame, respectively.

Oil volumes

Oil volume requirements for ball/ball and sleeve/ball bearings

This table shows the required amount of oil for oil-lubricated bearings.