Maintenance

Install the cartridge-type mechanical seal and seal-chamber cover

NOTICE:
Refer to the mechanical seal manufacturer’s drawings and instructions for assistance during
the installation of the mechanical seal.

1. Remove the impeller.

a) Loosen and remove the impeller nut.

The impeller nut has left-hand threads.

b) Remove the impeller, impeller key, and seal-chamber cover as described in the

Disassembly section.

2. Lubricate all O-rings with suitable lubricant, unless the seal manufacturer’s instructions

indicate otherwise.

3. Slide the cartridge seal assembly (rotary, stationary gland, gland gasket, and sleeve) onto

the shaft.

NOTICE:
Ensure that the mechanical-seal gland-piping connections are properly oriented.

122

Shaft

184

Seal-chamber cover

228

Bearing frame

355

Gland stud nut

370H

Bearing-frame bolts

4. Install the seal-chamber cover.

a) Set up a sling to the eyebolt and to the overhead lifting device.
b) Lift the seal-chamber cover and position it so that it aligns with the shaft.
c) Install the seal-chamber cover on the power end by guiding the cover carefully over the

cartridge-seal rotary.
Ensure that the gland studs smoothly enter the holes in the cartridge-seal gland and
that the cover fits into the bearing frame lock.

d) Install the seal-chamber cover and bearing-frame bolts and tighten them using an

alternating pattern.
Torque the bolts to the values shown in the Maximum torque values for 3700 fasteners
table.

e) Install the gland stud nuts and tighten evenly to the torque values shown in the

Maximum torque values for 3700 fasteners table.

5. Tighten the setscrews in the locking collar.