Maintenance

You can use penetrating oil if the adapter to the casing joint is corroded.

184

Seal chamber cover

418

Jackscrew

3. Remove the back pull-out assembly using a lifting sling through the bearing frame.

4. Remove and discard the casing gasket.

You will insert a new casing gasket during reassembly.

5. Remove the jackscrews.
6. Clean all gasket surfaces.

Clean surfaces prevent the casing gasket from partially adhering to the casing due to
binders and adhesives in the gasket material.

7. Secure the back pull-out assembly to prevent movement during transport.
8. Transport the back pull-out assembly to a clean work area for further disassembly.

Remove the coupling hub

1. If the coupling hub overhangs the shaft, mark the shaft for relocating the coupling hub

during reassembly.
Coupling hubs are normally mounted flush with the end of the shaft.

2. Remove the coupling hub using a spanning-type puller or puller holes provided in the hub.

Refer to the coupling manufacturer's instructions for assistance.

Remove the impeller (3700/3710)

CAUTION:
Wear heavy work gloves when you handle impellers. The sharp edges can cause physical injury.

1. Loosen the set screw at the end of the impeller nut.
2. Loosen and remove the impeller nut.

60

Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance