Commissioning, Startup, Operation, and Shutdown

8. Slightly spread the opening of the remaining coupling guard half and place it over the

installed coupling guard half so that the annular groove in the remaining coupling guard half
faces the driver.

1. Annular groove
2. Coupling guard half
3. Driver

9. Place the end plate over the driver shaft and locate the end plate in the annular groove at

the rear of the coupling guard half.

1. Annular groove
2. End plate

10. Repeat steps 5 through 7 for the rear end of the coupling guard half, except that you hand

tighten the nut.

Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance

45

Manual