Maintenance

2. Inspect it.
3. Replace worn parts.

Bearing maintenance

These bearing lubrication sections list different temperatures of the pumped fluid. If the pump is
ATEX-certified and the temperature of the pumped fluid exceeds the permitted temperature
values, then consult your ITT representative.

Bearing lubrication schedule

Type of bearing

First lubrication

Lubrication intervals

Oil-lubricated bearings

Add oil before you install and start After the first 200 hours, change
the pump. Change the oil after

the oil every 2000 operating hours

200 hours for new bearings.

or every three months.

Mechanical-seal maintenance

WARNING:
The mechanical seal used in an Ex-classified environment must be properly certified. Prior to startup,
make sure that all areas that could leak pumped fluid to the work environment are closed.

CAUTION:
Never operate the pump without liquid supplied to mechanical seal. If you run a mechanical seal dry,
even for a few seconds, this can cause seal damage. Physical injury can occur if a mechanical seal fails.

NOTICE:

• Sealing systems that are not self-purging or self-venting, such as plan 23, require manual

venting prior to operation. Failure to do so will result in excess heat generation and seal
failure.

• Cooling systems, such as those for bearing lubrication and mechanical-seal systems, must

be operating properly to prevent excess heat generation, sparks, and premature failure.

• The mechanical seal must have an appropriate seal flush system or excess heat

generation and seal failure can occur.

Cartridge-type mechanical seals

Cartridge-type mechanical seals are commonly used. Cartridge seals are preset by the seal
manufacturer and require no field settings. Cartridge seals installed by the user require
disengagement of the holding clips prior to operation, allowing the seal to slide into place. If the
seal has been installed in the pump by ITT, these clips have already been disengaged.

Other mechanical seal types

For other types of mechanical seals, refer to the instructions provided by the seal manufacturer
for installation and setting.

Before you start the pump

Check the seal and all flush piping.

Mechanical seal life

The life of a mechanical seal depends on the cleanliness of the pumped fluid. Due to the
diversity of operating conditions, it is not possible to give definite indications as to the life of a
mechanical seal.

Model 3700, API Type OH2 / ISO 13709 1st and 2nd Ed. / API 610 8/9/10/11th Ed. Installation, Operation, and Maintenance