2. Check that the oil level is correct. The correct oil level is centered in the bullseye sight

glass, when the pump is not in operation. During operation, bullseye sight gives a false oil
level reading. Shown is general schematic. Oil level is below outer race of bearing.

1. Plug
2. Reservoir
3. Main body

Lubricate the bearings with pure or purge-oil mist (optional)

NOTICE:
Do not expose an idle pump to freezing conditions. Drain all liquid that is inside the pump and
the cooling coils. Failure to do so can cause liquid to freeze and damage the pump.

Before lubricating with purge-oil mist, make sure that the bearing frame is properly lubricated.
See Lubricate the bearings with oil.
The oil requirements for ring-oil-lubricated bearings also apply to oil-mist-lubricated bearings.
1. Prepare the oil-mist generator according to the manufacturer's instructions.
2. Connect the oil-mist supply lines to the inlet connections.
3. Connect the drain and vent lines to the outlet connections.

1. Oil mist inlet
2. Oil mist outlet

Lubricate the bearings after a shutdown period

1. Flush out the bearings and bearing frame with a light oil to remove contaminants.

During flushing, make sure to rotate the shaft slowly by hand.

2. Flush the bearing housing with the proper lubricating oil to ensure oil quality after cleaning.
3. Refer to "Reassembly" section for proper bearing greasing procedure.