1 setting the machine, 6 connecting a control interface, 1 connecting the rs232 control interface – Kramer Electronics VS-3232A User Manual

Page 26: Setting the machine, Connecting a control interface, Connecting the rs-232 control interface, Table 7: machine # dip-switch settings, N 7.6, Table 7, On 7.5.1

Advertising
background image

VS-3232A 32x32 Audio Matrix Switcher Configurations

21

21

7.5.1 Setting the Machine #

To control a unit remotely via RS-232, RS-485, IR or the Ethernet, each unit
has to be identified via its unique Machine #. Set the Machine #

1

on a

VS-3232A unit according to

Table 7

.

Table 7: Machine # DIP-switch Settings

Mach. #

DIP 1

DIP 2

DIP 3

DIP 4

Mach. #

DIP 1

DIP 2

DIP 3

DIP 4

1

ON

OFF

OFF

OFF

9

ON

OFF

OFF

ON

2

OFF

ON

OFF

OFF

10

OFF

ON

OFF

ON

3

ON

ON

OFF

OFF

11

ON

ON

OFF

ON

4

OFF

OFF

ON

OFF

12

OFF

OFF

ON

ON

5

ON

OFF

ON

OFF

13

ON

OFF

ON

ON

6

OFF

ON

ON

OFF

14

OFF

ON

ON

ON

7

ON

ON

ON

OFF

15

ON

ON

ON

ON

8

OFF

OFF

OFF

ON

7.6 Connecting a Control Interface

You can connect a control interface (RS-232 or RS-485). It is recommended
that the control interfaces are identical on each switcher in the series of 32x32
matrix switchers; either RS-232 or RS-485 (one control interface suffices).
For example, in an interconnected varied-format 32x32 switcher application,
if the switcher that connects to the PC connects via the RS-232 control
interface, each switcher would interconnect via the RS-232 control interface
and not via the RS-485 control interface.

You may transfer from one interface to another via the Kramer VP-43xl
Interface Converter

2

. You can choose the RS-232 control interface, if the

range is less than 25 meters for each point-to-point connection.

For greater ranges, you can choose the RS-485 control interface, and operate
the switcher from an extended distance of up to 1000 meters.

7.6.1 Connecting the RS-232 Control Interface

You can connect several switchers (from the series of 32x32 or 16x16 matrix
switchers) and the control unit in an RS-232 daisy chain arrangement, with or
without using a Null-modem adapter, as

Figure 15

illustrates.

The RS-232 daisy chain switcher arrangement is transparent. This lets you arrange
the switchers (from the series of 32x32 or 16x16 matrix switchers) according to
your requirements, and not according to a fixed sequence dependent on the
Machine #.

1 When using a single unit, set the unit to MACHINE # 1

2 For more information on the VP-43xl, go to our Web site at

http://www.kramerelectronics.com

Advertising