The MENU Commands

43

43

9.7 Selecting the Initialization Sequence Delay Time for a Slave Unit

When several VS-3232A units are used together, it is necessary to set up the
delay time of each slave unit.

To configure the Initialization sequence delay time

1

:

1. Turn the machine OFF.

2. Set DIP 6 to OFF (Master unit).

3. Turn the machine ON.

The unit is now set to the Master Mode.

4. Set the delay time according to

Table 14

, using the front-panel buttons and

the LCD.

5. Turn the machine OFF.

6. Set DIP 6 to ON (Slave unit).

7. Turn the Machine ON.

Table 14

defines the initialization sequence delay time per unit in a

Master/Slave configuration setup

Table 14: Initialization Sequence Delay Time

The Number of the Slave unit in

the Sequence:

Required Turn-ON Time

[sec]

Notes

1

st

5

The delay time is set to 5 seconds

automatically

2

nd

10

Set via the Turn-ON menu

3

rd

15

4

th

20

9.8 The Main Firmware Version

The main firmware version menu shows information regarding the latest main
and Ethernet firmware versions, for example:

Main Firmware Version: 1.00

Ethernet Version: Use Config. Manager

This information lets you decide whether a firmware upgrade is required.

It is recommended to upgrade the firmware only after consulting with the

Kramer technical support staff


1 Turn-ON time