Communication protocols – Kramer Electronics VS-3232A User Manual

Page 67

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Communication Protocols

62

"X": Connect on a LEVEL

The command "X" is used to request that a connection be made on a user defined
level. It must be followed by an output number, a comma, an input number, a comma
and a level number.

The level number must be identical to the machine number set by the DIP-switches
on the rear panel.

The command: ** X2,29,3!!

connects output 2 to input 29 in router machine number 3 and returns the following
string:

** OK !!

indicating that the router performed the requested connection.

The command: ** X2,17,1 Y32,-,1 X7,6,1!!

connects output 2 with input 17, disconnects output 32 and connects output 7 with
input 6 in router Machine number 1 and returns the following string:

** OK !!

"P": Preset a Salvo Connect Sequence

The command "P" is used to set up a salvo, which is a series of connect commands
for later execution with the "T" command.

The command: **P29!!

stores full matrix setup in address 29 (1-59) of non-volatile memory and returns the
following string:

** OK !!

"T": Trigger a Salvo Connect Sequence

The command "T" is used to recall a salvo, which is a series of connect commands
for previously stored status with the "P" command

The command: **T29!!

restores full matrix setup from address 29 (1-59) of non-volatile memory and return
the following string:

** OK !!


















Advertising