8.1.4 AS-Interface

assembly

/ Installation of PCBs

Tool:

VS18/VS26

Philips screwdriver size 1


1. Important: Make sure valves are not already mounted on the valve island, because the AS-

Interface PCB (B) as well as the expansion PCB (C) could become damaged during
assembly.

2. Insert the AS-Interface PCB (B) in the middle groove of the left end plate and the modular

sub-bases. Consider, that the single station expansion PCB (C), different from the main
PCB (B), has to be inserted in the left groove of the left end plate and the modular sub-
bases. Check to make sure the plug-in connection on the PCB is centred with the orifice to
the valve interface.

3. Plug the lowest connector of the Fieldbus E-connector-kit (A) into the connector on the AS-

Interface PCB (B).

4. Plug the other connector of the Fieldbus E-connector-kit (A) into the upper connector on the

AS-Interface PCB (B).

5. Ensure connector-kit gasket is fitted on the left end plate.

6. Mount the Fieldbus E-connector-kit (A) with two mounting screws on the left end plate.

Tighten the screws then with the specified torque. If you are using a power screwdriver
consider the maximum speed allowed.

7. Ensure gasket on the bottom of the LED window (D) is fitted and place the LED window on

the left end plate. Turn mounting screws by hand in the existing threads and tighten then by
hand.


























Screw

Type
(thread)

Valve
seize

Tightening
torque in Nm

Tightening
torque in Ibs

Max. screw driver
speed in r.p.m.

13 M3x8

VS18/
VS26

0.8 – 0.9

7.08 – 7.96

1100

17 M3x8

VS18/
VS26

0.4

3.54

Tighten by hand!