VS18/VS26

MAINTENANCE & INSTRUCTION BOOKLET

8.5 I

NTERBUS

-S

Norgren Interbus-S Fieldbus systems conform to DIN19258.

Communication system:

4-wire RS422 hardware
communication protocol

Number of nodes per network:

Master + 512 nodes including
remote slaves

Total number of I/O per network:

4096

Bus topology:

Ring


Note:

• VS18/VS26 Interbus-S valve islands are intended for connection to the Interbus-S remote

bus system only.

• The valve island must be mounted on an earthed base to meet the EMC directives.

8.5.1 Interbus-S pin assignment

Male D-Sub 9-pin (IP65)

Female D-Sub 9-pin (IP65)

Pin no.

Function

Pin no.

Function

1 DO

1 DO

2 DI

2 DI

3 0VI

3 0VI

4 -

4 -

5 -

5 -

6 /DO

6 /DO

7 /DI

7 /DI

8 -

8 -

9 -

9 -


The VS18/VS26 Interbus-S valve islands do automatically recognize whether an additional
device is connected on the outgoing connector or not. It is not necessary to add a bridge
between pin 5 and pin 9.

Male

Female

Communication in

Communication out

Looking into node connector