B&B Electronics Zlinx ZP Series User Manual

Page 28

Advertising
background image

24

Manual Documentation Number: ZP24D-250RM-SR-2508

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

results for a 13 channel scan:
If SD = 0, time = 0.18 sec
SD = 8, time = 47.19 sec
SD = 2, time = 0.74 sec
SD = 10, time = 3.15 min
SD = 4, time = 2.95 sec
SD = 12, time = 12.58 min
SD = 6, time = 11.80 sec
SD = 14, time = 50.33 min

A1 ( v1.x80*)

Networking
{Association}

End Device Association.
Set/Read End Device association
options.
bit 0 - ReassignPanID
0 - Will only associate with
Coordinator operating on PAN ID
that matches module ID
1 - May associate with
Coordinator operating on any
PAN ID
bit 1 – ReassignChannel
0 - Will only associate with
Coordinator operating on
matching CH Channel setting
1 - May associate with
Coordinator operating on any
Channel
bit 2 – AutoAssociate
0 - Device will not attempt
Association
1 - Device attempts Association
until success
Note: This bit is used only for
Non-Beacon systems. End

Devices in Beacon-enabled
system must always associate to
a Coordinator
bit 3 – PollCoordOnPinWake
0 - Pin Wake will not poll the
Coordinator for indirect (pending)
data
1 - Pin Wake will send Poll
Request to Coordinator to extract
any pending data bits 4 - 7 are
reserved

0 - 0x0F [bitfield]

0

A2 ( v1.x80*)

Networking
{Association}

Coordinator Association.
Set/Read Coordinator association
options.
bit 0 – ReassignPanID
0 - Coordinator will not perform
Active Scan to locate
available PAN ID. It will
operate on ID (PAN ID).
1 - Coordinator will perform
Active Scan to determine
an available ID (PAN ID). If
a PAN ID conflict is found,
the ID parameter will

0 - 7 [bitfield]

0

Advertising