A1 (End Device Association) Command
<Networking {Association}> The A1
command is used to set and read
association options for an End Device.

Use the table below to determine End
Device
behavior in relation to the A1 parameter.
















A2 (Coordinator Association) Command

<Networking {Association}> The A2
command is used to set and read association
options of the Coordinator.

Use the table below to determine
Coordinator
behavior in relation to the A2 parameter.

AT Command: ATA1

Parameter Range: 0 - 0x0F [bitfield]

Default Parameter Value: 0

Related Commands: ID (PAN ID), NI
(Node Identifier), CH (Channel), CE
(Coordinator Enable), A2 (Coordinator
Association)
Minimum Firmware Version Required:
v1.x80

Bit number

End Device Association Option

0 - ReassignPanID

0 - Will only associate with Coordinator operating on PAN ID that matches Node
Identifier
1 - May associate with Coordinator operating on any PAN ID

1 - ReassignChannel

0 - Will only associate with Coordinator operating on Channel that matches CH setting
1 - May associate with Coordinator operating on any Channel

2 - AutoAssociate

0 - Device will not attempt Association
1 - Device attempts Association until success_ Note: This bit is used only for Non-
Beacon systems. End Devices in a Beaconing system must always associate to a
Coordinator

3 -
PollCoordOnPinWake

0 - Pin Wake will not poll the Coordinator for pending (indirect) Data
1 - Pin Wake will send Poll Request to Coordinator to extract any pending data

4 - 7

[reserved]

AT Command: ATA2
Parameter Range: 0 - 7 [bitfield]

Default Parameter Value: 0
Related Commands: ID (PAN ID),
NI (Node Identifier), CH (Channel),
CE (Coordinator Enable), A1 (End
Device Association), AS Active
Scan), ED (Energy Scan)
Minimum Firmware Version
Required: v1.x80