B&B Electronics Zlinx ZP Series User Manual

Page 31

Advertising
background image

Manual Documentation Number: ZP24D-250RM-SR-2508

27

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

dBm)
TimeStamp<CR> (3 bytes)
<CR>
A carriage return <CR> is sent at
the end of the AS command. The
Active Scan is capable of
returning up to 5 PanDescriptors
in a scan. The actual scan time
on each channel is measured as
Time = [(2 ^SD PARAM) * 15.36]
ms. Note the total scan time is
this time multiplied by the number
of channels to be scanned. Also
refer to SD command description.

ED ( v1.x80*)

Networking

{Association}

Energy Scan. Send an Energy

Detect Scan. This parameter

determines the length of scan on

each channel. The maximal

energy on each channel is

returned & each value is followed

by a carriage return. An additional

carriage return is sent at the end

of the command. The values

returned represent the detected

energy level in units of -dBm. The
actual scan time on each channel

is measured as Time = [(2 ^ED) *

15.36] ms. Note the total scan

time is this time multiplied by the

number of channels to be

scanned (refer to SD parameter).

0 - 6

-

EE ( v1.xA0*)

Networking
{Security}

AES Encryption Enable.
Disable/Enable 128-bit AES
encryption support. Use in
conjunction with the KY
command.

0 - 1

0
(disabled)

KY ( v1.xA0*)

Networking
{Security}

AES Encryption Key. Set the
128-bit AES (Advanced
Encryption Standard) key for
encrypting/decrypting data. The
KY register cannot be read.

0 - (any 16-Byte
value)

-

*Firmware version in which the command was first introduced (firmware versions are
numbered in hexadecimal notation.)

Commands-RF Interfacing

AT_
Command

Command_
Category

Name and
Description

Parameter
Range

Default

PL

RF Interfacing

Power Level. Select/Read the
power level at which the RF
module transmits conducted
power.

0 - 4
0 = -10 / 10 dBm
1 = -6 / 12 dBm
2 = -4 / 14 dBm
3 = -2 / 16 dBm
4 = 0 / 18 dBm

4

CA (v1.x80*)

RF Interfacing

CCA Threshold. Set/read the
CCA (Clear Channel
Assessment) threshold. Prior to
transmitting a packet, a CCA is

0 - 0x50 [-dBm]

0x2C
(-44d dBm)

Advertising