D6 (DIO6 Configuration)
Command
<I/O Settings> The D6 command
is used to select/read the behavior
of the DIO6 line (pin 16).
Options include:

• RTS flow control
• Analog-to-digital

converter

• Digital input
• Digital output





D7 (DIO7 Configuration)
Command
<I/O Settings> The D7 command
is used to select/read the behavior
of the DIO7 line (pin 12).
Options include:

• CTS flow control
• Analog-to-digital
converter
• Digital input
• Digital output






D8 (DI8 Configuration)
Command
<I/O Settings> The D8 command
is used to select/read the behavior
of the DI8 line (pin 9).
This command enables configuring
the pin to function as a digital
input. This line is also used
with Pin Sleep.




AT Command: ATD6

Parameter Range:0 - 5

Parameter Configuration

0

Disabled

1

RTS Flow Control

2

n/a

3

DI

4

DO low

5

DO high

Default Parameter Value:0

Parameters 3-5 supported as of firmware
version 1.xA0

AT Command: ATD7

Parameter Range:0 - 5

Parameter Configuration

0

Disabled

1

CTS Flow Control

2

n/a

3

DI

4

DO low

5

DO high

Default Parameter Value:1

Parameters 3-5 supported as of firmware version
1.x.A0

AT Command: ATD8

Parameter Range:0 - 5 _ (1, 2, 4 & 5 n/a)

Parameter Configuration

0

Disabled

3

DI

Default Parameter Value:0

Minimum Firmware Version Required: 1.xA0