received. The PWM output will also be set low at power-up until the first RF packet is
received. A parameter value of 0xFF permanently enables the PWM output and it will
always reflect the value of the last received RF packet.


RR Command
<Networking {Addressing}> The
RR command is used set/read the
maximum number of retries the
module will execute in addition to
the 3 retries provided by the
802.15.4 MAC.

This values does not need to be set on all modules for retries to work. If retries are
enabled, the transmitting module will set a bit in the B&B RF Packet header which
requests the receiving module to send an ACK (acknowledgement). If the transmitting
module does not receive an ACK within 200 msec, it will re-send the packet within a
random period up to 48 msec. Each retry can potentially result in the MAC sending
the packet 4 times (1 try plus 3 retries). Note that retries are not attempted for packets
that are purged when transmitting with a Cyclic Sleep Coordinator.


SC (Scan Channels) Command
<Networking {Association}> The
SC command is used to set and
read the list of channels to scan
for all Active and Energy Scans as
a bit field.

This affects scans initiated in
command mode [AS (Active Scan)
and ED (Energy Scan) commands]
and during End Device Association
and Coordinator startup.

bit 0 - 0x0B

bit 4 - 0x0F bit

8 - 0x13 bit

12 - 0x17

bit 1 - 0x0C

bit 5 - 0x10

bit 9 - 0x14

bit 13 - 0x18

bit 2 - 0x0D

bit 6 - 0x11

bit 10 - 0x15

bit 14 - 0x19

bit 3 - 0x0E

bit 7 - 0x12

bit 11 - 0x16

bit 15 - 0x1A



SD (Scan Duration) Command
<Networking {Association}> The
SD command is used to set and
read the exponent value that
determines the duration (in time) of
a scan.

End Device (Duration of Active
Scan during Association) - In a
Beacon system, set SD = BE of
the Coordinator. SD must be set at least to the highest BE parameter of any
Beaconing Coordinator with which an End Device or Coordinator wish to discover.


AT Command: ATRR

Parameter Range: 0 - 6

Default: 0

Minimum Firmware Version Required: 1.xA0

AT Command: ATSC

Parameter Range: 0 - 0xFFFF

Default Parameter Value: 0x1FFE

Related Commands: ED (Energy Scan), SD (Scan
Duration)

Minimum Firmware Version Required: v1.x80

AT Command: ATSD

Parameter Range: 0 - 0x0F

Default Parameter Value: 4

Related Commands: ED (Energy Scan), SC
(Scan Channel)

Minimum Firmware Version Required: v1.x80