D0 - D4 (DIOn Configuration) Commands
<I/O Settings> The D0, D1, D2, D3 and D4
commands are used to select/read the
behavior of their respective AD/DIO lines
(pins 20, 19, 18, 17 and 11 respectively).
Options include:

• Analog-to-digital converter
• Digital input
• Digital output














D5 (DIO5 Configuration) Command
<I/O Settings> The D5 command is used to
select/read the behavior of the DIO5 line
(pin 15).
Options include:

• Associated Indicator (LED blinks
when the module is associated)
• Analog-to-digital converter
• Digital input
• Digital output











AT Commands: _ ATD0, ATD1,
ATD2, ATD3, ATD4

Parameter Range:0 - 5

Parameter Configuration

0

Disabled

1

n/a

2

ADC

3

DI

4

DO low

5

DO high

Default Parameter Value:0

Minimum Firmware Version
Required: 1.x.A0

AT Command: ATD5
Parameter Range:0 - 5

Parameter

Configuration

0

Disabled

1

Associated

Indicator

2

ADC

3

DI

4

DO low

5

DO high

Default Parameter Value:1

Parameters 2-5 supported as of
firmware version 1.xA0