B&B Electronics Zlinx ZP Series User Manual

Page 51

Advertising
background image

Manual Documentation Number: ZP24D-250RM-SR-2508

47

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

FP (Force Poll) Command
<Networking (Association)> The
FP command is used to request
indirect messages being held by a
Coordinator.

FR (Software Reset) Command
<Special> The FR command is
used to force a software reset on
the RF module. The reset simulates powering off and then on again the module.


GT (Guard Times) Command
<AT Command Mode Options>
GT Command is used to set the DI
(data in from host) time-of-silence
that surrounds the AT command
sequence character (CC
Command) of the AT Command
Mode sequence (GT + CC + GT).

The DI time-of-silence is used to
prevent inadvertent entrance into
AT Command Mode.

Refer to the Command Mode section for more information regarding the AT
Command Mode Sequence.


HV (Hardware Version)
Command
<Diagnostics> The HV command
is used to read the hardware
version of the RF module.


IA (I/O Input Address) Command
<I/O Settings {I/O Line Passing}>
The IA command is used to bind a
module output to a specific
address. Outputs will only change
if received from this address. The
IA command can be used to
set/read both 16 and 64-bit
addresses.

Setting all bytes to 0xFF will not allow the reception of any I/O packet to change
outputs. Setting the IA address to 0xFFFF will cause the module to accept all I/O
packets.






AT Command: ATFP

Minimum Firmware Version Required: v1.x80

AT Command: ATFR

Minimum Firmware Version Required: v1.x80

AT Command: ATGT

Parameter Range:2 - 0x0CE4 [x 1 millisecond]

Default Parameter Value:0x3E8 _ (1000 decimal)

Related Command: CC (Command Sequence
Character)

AT Command: ATHV

Parameter Range:0 - 0xFFFF [Read-only]

Minimum Firmware Version Required: v1.x80

AT Command: ATIA

Parameter Range:0 - 0xFFFFFFFFFFFFFFFF

Default Parameter
Value:0xFFFFFFFFFFFFFFFF_ (will not allow any
received I/O packet to change outputs)

Minimum Firmware Version Required: v1.xA0