Bit number End Device Association Option

0 -
ReassignPanID

0 - Coordinator will not perform Active Scan to locate available PAN ID. It will operate on
ID (PAN ID).
1 - Coordinator will perform Active Scan to determine an available ID (PAN ID). If a PAN
ID conflict is found, the ID parameter will change.

1 -
ReassignChannel

0 - Coordinator will not perform Energy Scan to determine free channel. It will operate on
the channel determined by the CH parameter.
1 - Coordinator will perform Energy Scan to find a free channel, then operate on that
channel.

2 -AllowAssociate

0 - Coordinator will not allow any devices to associate to it.
1 - Coordinator will allow devices to associate to it.

3 - 7

[reserved]


AC (Apply Changes) Command
<AT Command Mode Options> The AC
command is used to explicitly apply
changes to module parameter values.
‘Applying changes’ means that the module is
re-initialized based on changes made to its parameter values. Once changes are
applied, the module immediately operates according to the new parameter values.

This behavior is in contrast to issuing the WR (Write) command. The WR command
saves parameter values to non-volatile memory, but the module still operates
according to previously saved values until the module is re-booted or the CN (Exit AT
Command Mode) command is issued.

Refer to the “AT Command - Queue Parameter Value” API type for more information.

AI (Association Indication) Command
<Networking {Association}> The AI
command is used to indicate occurrences
of errors during the last association
request.

Use the table below to determine meaning
of the returned values.



AT Command: ATAC
Minimum Firmware Version
Required: v1.xA0

AT Command: ATAI
Parameter Range: 0 - 0x13
[read-only]
Related Commands: AS (Active Scan),
ID (PAN
ID), CH (Channel), ED (Energy Scan),
A1 (End
Device Association), A2 (Coordinator
Association), CE (Coordinator Enable)
Minimum Firmware Version Required:
v1.x80

Advertising