Manual Documentation Number: ZP24D-250RM-SR-2508

29

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

SP

Sleep_ (Low
Power)

Cyclic Sleep Period.<NonBeacon

firmware> Set/Read sleep period
for cyclic sleeping remotes.
Coordinator and End Device SP
values should always be equal. To
send Direct Messages, set SP = 0.
End Device- SP determines the
sleep period for cyclic sleeping
remotes. Maximum sleep period is
268 seconds (0x68B0).
Coordinator- If non-zero, SP
determines the time to hold an
indirect message before discarding
it. A Coordinator will discard
indirect messages after a period of
(2.5 * SP).

0 - 0x68B0 [x
10 ms]

0

DP (1.x80*)

Sleep_ (Low
Power)

Disassociated Cyclic Sleep
Period.
<NonBeacon firmware> _
End Device - Set/Read time period
of sleep for cyclic sleeping remotes
that are configured for Association
but are not associated to a
Coordinator. (i.e. If a device is
configured to associate, configured
as a Cyclic Sleep remote, but does
not find a Coordinator, it will sleep
for DP time before reattempting
association.) Maximum sleep
period is 268 seconds (0x68B0).
DP should be > 0 for NonBeacon
systems.

1 - 0x68B0 [x
10 ms]

0x3E8_
(1000d)

*Firmware version in which the command was first introduced (firmware versions are
numbered in hexadecimal notation.)



Commands-Serial Interfacing

AT_
Command

Command_
Category

Name and Description

Parameter
Range

Default

BD

Serial _

Interfacing

Interface Data Rate. Set/Read the
serial interface data rate for
communications between the RF
module serial port and host.
Request non-standard baud rates
with values above 0x80 using a
terminal window. Read the BD
register to find actual baud rate
achieved.

0 - 7 (standard
baud rates)
0 = 1200 bps
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
0x80 - 0x1C200
(non-standard
baud rates)

3

RO

Serial _
Interfacing

Packetization Timeout. Set/Read
number of character times of inter-
character delay required before

0 - 0xFF
[x character
times]

3