P0 (PWM0 Configuration)
Command
<I/O Setting {I/O Line Passing}>
The P0 command is used to
select/read the function for
PWM0 (Pulse Width Modulation
output 0). This command enables
the option of translating
incoming data to a PWM so that
the output can be translated back
into analog form.

With the IA (I/O Input Address)
parameter correctly set, AD0
values can automatically be
passed to PWM0.


P1 (PWM1 Configuration)
Command
<I/O Setting {I/O Line Passing}>
The P1 command is used to
select/read the function for
PWM1 (Pulse Width Modulation
output 1). This command enables
the option of translating incoming
data to a PWM so that the output
can be translated back into analog
form.

With the IA (I/O Input Address)
parameter correctly set, AD1 values can automatically be passed to PWM1.



PL (Power Level) Command
<RF Interfacing> The PL
command is used to select and
read the power level at which the
RF
module transmits conducted
power.

WHEN OPERATING IN EUROPE:
modem must be configured to
operate at a maximum transmit
power output
level of 10 dBm. The PL parameter
must equal “0” (10 dBm).
Additionally, European regulations stipulate an EIRP power maximum of 12.86 dBm
(19 mW) for the modem and 12.11 dBm for the modem when integrating high-gain
antennas.





AT Command: ATP0_ The second character in
the command is the number zero (“0”), not the
letter “O”.

Parameter Range: 0 - 2

Parameter Configuration

0

Disabled

1

RSSI

2

PWM0 Output

Default Parameter Value: 1

AT Command: ATP1

Parameter Range: 0 - 2

Parameter Configuration

0

Disabled

1

RSSI

2

PWM1 Output

Default Parameter Value: 0

Minimum Firmware Version Required: v1.xA0

AT Command:

ATPL

Parameter Range:

0 - 4

Parameter

0

-10 dBm

10 dBm

1

-6 dBm

12 dBm

2

-4 dBm

14 dBm

3

-2 dBm

16 dBm

4

0 dBm

18 dBm

Default Parameter Value: 4