Stainless Max Series Pumps

7-1

Installation

SECTION

7

: INSTALLATION

OVERVIEW

This section provides guidelines and recommendations for installing a
Stainless Max Pump Assembly into your truck chassis.

FRAME MOUNTING

Also see “Installation and Parts Drawings,” located at the back of this
manual for more detail.

Plate # 994AB – Sheet 1: Pedestal, with HG Gearbox

Sheet 2: Pedestal only

Plate # 1043AB – SMD -A Series Pump, with HG Gearbox

Plate # 1041AB – SMD-X Series Pump, with X Gearbox

IMPORTANT !

TO FULLY SUPPORT THE STAINLESS MAX PUMP ASSEMBLY, USE ALL
MOUNTING BOLT HOLES PROVIDED IN THE GEARBOX AND/OR
PEDESTAL MOUNT.

Mounting Holes

Mounting varies depending on assembly configuration, i.e., pedestal
mount with or without gearbox, or the type of gearbox used. Mount-
ing holes are as follows:

Pedestal mount –

four mounting pads with 0.669” (17 mm)
clearance holes

HG Gearbox –

eight 1/2-13 tapped holes, 0.75”
(10.05 mm) deep, located on the front
face of the unit

X Series Gearbox – four (two each side) 5/8-11 tapped holes,

1.25” (31.8 mm) deep

DRIVELINE ISSUES

Due to the increasing sophistication of fire apparatus and truck design,
there has been an increase in the number of reported driveline
problems.