Preventive Maintenance

4-2

Stainless Max Series Pumps

During Freezing Weather

In freezing weather, drain the pump as follows:

1. Open all discharge and suction valves, remove suction tube

caps, and discharge valve caps.

2. Open pump body drain cocks and/or Hale multiple drain valve.

3. After the pump is completely drained, replace all caps and close

all valves.

After Pumping from Salt Water, Contaminated Water, or
with Foam Solution

After drafting from sea water, contaminated, sandy or dirty water,
flush the pump and suction hoses by using water from a hydrant
or other clean water source.

After pumping foam through the pump, flush as above until all
residues of foam are flushed.

AFTER EACH USE

Check seals for leaks.

Check piping for leaks.

Close all valves and caps.

WEEKLY

Test the relief valve system

Test the priming system

Test the pump shift warning indicator lights

Valve Maintenance

Check and clean the intake strainers

Check any auxiliary engine.

Verify all gauges are in working order

Operate pump controls

Inspect water and foam tanks

Check roof and bumper turrets

Check auxiliary fire suppression equipment