Figure 4-5: grade 8 bolt head 8, Indicator light test, Annually – Hale SMR User Manual

Page 60: Replace gearbox oil

Advertising
background image

Preventive Maintenance

4-8

Stainless Max Series Pumps

2. All bolts are tight. Use a torque wrench to

torque bolts to the drive train manufacturer's
recommended specifications.

3. Bolts used are “Grade 8” strength. Be sure to

use Hale genuine replacement parts before you
attempt any repair maintenance.

Indicator Light Test

Operate the respective component having indicator lights and
observe the indicator light operation. If the light fails to tunr ON,
check and/or replace the bulb and test again.

ANNUALLY

Replace the pump gearbox oil. (See Table 4-2: “Recommended
Lubricants” on page 4-6.)

Check individual drain lines from the pump to the multi-drain to
ensure proper drainage and protection from freezing.

Test tank-to-pump flow rate.

Clean ESP Primer if installed.

Perform the yearly pump test to check performance levels. (See
NFPA Standard 1911 for more details.)

Replace Gearbox Oil

1. Drain the oil from the

gearbox.

2. Remove the drain plug

(magnetic) and drain the
gearbox oil into a
suitable container. See
Figure 4-6: “Sample,
Drain and Fill Plugs –
RH Horizontal Installa-
tion.” Also See Figure
4-2: “Recommended
Lubricants,” on page 4-
6, for fluid quantities.

Figure 4-5:

Grade 8 Bolt

Head

Figure 4-6: Sample, Drain, Fill and Level

Detect Plugs - RH Horizontal Installation

Water Drain

Oil

Drain

Oil Fill

Oil Fill

Level

Advertising
This manual is related to the following products:

SMD, SMM