Hale SMR User Manual

Page 51

Advertising
background image

Stainless Max Series Pumps

3-17

Operating Procedures

5. Drain the pump (especially important in freezing weather):

Open the discharge valves, remove suction tube caps, and
discharge valve caps.

Open the pump body drain cocks or Hale multiple drain valve.
If a multiple drain valve is used, all pump drain lines should be
connected to this valve.

After the pump is completely drained, replace all caps and
close all valves,

7. If sea water, dirty water, alkaline water or foam solution, has

been used, flush the pump with clean water.

8. Remove the wheel chocks only when preparing to leave the

scene.

9. Fill out the Pump Run Log, indicating total pumping time and total

out-of-station time.

10. Report all pump, vehicle and equipment malfunctions, and irregu-

larities to the proper authority.

11. Know and follow all local procedures.

Advertising
This manual is related to the following products:

SMD, SMM