Installing pump and gearbox to apparatus – Hale SMR User Manual

Page 86

Advertising
background image

Maintenance and Repair

6-8

Stainless Max Series Pumps

4. Place and support the pump assembly on a stable work stand /

bench of suitable capacity (see

WARNING !

on page 6-7). Have

the air vent and covers exposed to provide easy and safe access
to the internal parts.

Installing Pump Assembly to Apparatus

After completing repairs and /or maintenance, install the pump
assembly to the apparatus before filling with oil.

1. First, review preceding section “Before You Begin...,” beginning

on page 6-1.

2. Attach proper supporting devices and stabilize the assembly for

transport to the apparatus.

3. Place the pump assembly into position within the apparatus.

4. Connect the mounting brackets using the proper fasteners.

Torque the fasteners to values provided in Table 6-2: “Torque
Values” on page 6-2.

5. Connect the drive shaft to the gearbox/pedestal. Apply Loctite to

the fasteners and torque to PTO manufacturer's specifications.

6. Fill the gearbox and /or pedestal, if included, to the proper oil

level. See Section 4: “Preventive Maintenance,” heading “Annu-
ally,” beginning on page 4-8 and add oil to the gearbox and/or
the pedestal.

Use only oil with an API GL-5 rating. See Table 6-2: “Recom-
mended Lubricants” on page 6-2 for recommended oils and
gearbox/pedestal capacities.

7. Reassemble and reconnect all components removed to gain

access to the pump assembly, paying particular attention to your
sketch and identification match markings/tags.

8. Test the pump for proper operation per your departmental re-

quirements. Note and repair any leaks.

9. Recheck and top off oil levels. See Section 4: “Preventive Main-

tenance,” heading “Annually,” beginning on page 4-8 and add oil
to the gearbox and/or the pedestal.

10. Return the apparatus to normal operation.