12 [source]:sweep subsystem, Sour, Ubsystem – BNC 835 Programmer Manual User Manual

Page 43: Source]:sweep subsystem

Advertising
background image


Berkeley Nucleonics Corporation 2955 Kerner Blvd., San Rafael, CA 94901

Phone: 415-453-9955, Fax: 415-453-9956, Email: [email protected], Web: www.berkeleynucleonics.com

5.12

[SOURce]:SWEep Subsystem

Command

Parameters

Unit (default)

Remark

[SOURce]:SWEep:COUNt

INFinite|<value>

INFinite

[SOURce]:SWEep:DIRection

UP|DOWN|RANDom

UP

[SOURce]:SWEep:POINts

2 to 65535

[SOURce]:SWEep:DWELl

<value>

s

[SOURce]:SWEep:DELay

<value>

s

[SOURce]:SWEep:DELay:AUTO

ON|OFF|1|0

ON

[SOURce]:SWEep:PROGress?

[SOURce]:SWEep:SPACing

LINear|LOGarithmic

[SOURce]:FREQuency:MODE

FIXed|CW|SWEep|LIST

[SOURce]:FREQuency:STARt

fmin to fmax

Hz

[SOURce]:FREQuency:STOP

fmin to fmax

Hz

[SOURce]:POWer:MODE

FIXed|LIST|SWEep

[SOURce]:POWer:STARt

<value>

dBm

[SOURce]:POWer:STOP

<value

dBm

:SWEep:COUNt INFinite | <value>

[SOURce]:SWEep:COUNt Infinite | <value>

[SOURce]:SWEep:COUNt?

This command sets the number of sweep repetitions being played after triggering a sweep. If set to

INFinite, the sweep will be repeated until a [SOURce]:FREQuency:MODE or [SOURce]:POWer:MODE

command is issued.

*RST INFinite

Range INFinite or 2-65535

:SWEep:DIRection UP|DOWN|RANDom

[SOURce]:SWEep:DIRection UP | DOWN | RANDom

:SWEep:POINts

[SOURce]:SWEep:POINts <value>

[SOURce]:SWEep:POINts?

This command defines the number of step sweep points.

*RST 101

Range 2–65535

:SWEep:DWELl

[SOURce]:SWEep:DWELl <value>

Advertising