BNC 835 Programmer Manual User Manual

Page 57

Advertising
background image


Berkeley Nucleonics Corporation 2955 Kerner Blvd., San Rafael, CA 94901

Phone: 415-453-9955, Fax: 415-453-9956, Email: [email protected], Web: www.berkeleynucleonics.com

TRIGger[:SEQuence]:TYPE NORMal | GATE | POINT

TRIGger[:SEQuence]:TYPE?

This command sets the trigger type that controls the waveform’s playback.

The following list describes the trigger type command choices:

NORMal

Upon triggering, the waveform sequence plays according to settlings defined

by :INITiate:CONTinuous (only once or repeatedly)

GATE

An external trigger signal repeatedly starts and stops the waveform’s

playback. The time duration for playback depends on the duty period of the

trigger signal and the gate polarity selection. The waveform plays during the

inactive state and stops during the active polarity selection state. The active

state can be set high or low. The gate mode works only with an external

trigger source.

POINt

Upon triggering, only a single point of the sweep (list) is played.

*RST NORM

:TRIGger[:SEQuence]:SOURce

TRIGger[:SEQuence]:SOURce IMMediate|KEY|EXTernal|BUS

TRIGger[:SEQuence]:SOURce?

This command sets the trigger source.

IMMediate

No waiting for a trigger event occurrs

KEY

This choice enables manual triggering by pressing the front-panel RFon/off.

EXTernal

This choice enables the triggering of a sweep event by an externally applied signal at

the MOD IN connector.

BUS

This choice enables triggering over the LAN using the *TRG or GET commands.

*RST IMM

:TRIGger[:SEQuence]:DELay

TRIGger[:SEQuence]:DELay <value>

TRIGger[:SEQuence]:DELay?

This command sets the amount of time to delay the BENCHTOP MICROWAVE SOURCE response to

an external trigger.

The delay is a path (time) delay between when the BENCHTOP MICROWAVE SOURCE receives the

trigger and when it responds to the trigger. The delay does not occur until you turn it on. You can set

the delay value either before or after turning it on.

:TRIGger[SEQuence]:SLOPe

TRIGger[:SEQuence]:SLOPe POSitive|NEGative|NP|PN

TRIGger[:SEQuence]:EXTernal:SLOPe?

This command sets the polarity for an external trigger signal while using the continuous, single

triggering mode. The POSitive and NEGative selections correspond to the high (positive) and low

(negative) states of the external trigger signal. For example, when you select POSitive, the waveform

Advertising
This manual is related to the following products: