14 [source]:fm subsystem (frequency modulation), Sour, Ubsystem – BNC 835 Programmer Manual User Manual

Page 47: Requency, Odulation, Source]:fm subsystem (frequency modulation)

Advertising
background image


Berkeley Nucleonics Corporation 2955 Kerner Blvd., San Rafael, CA 94901

Phone: 415-453-9955, Fax: 415-453-9956, Email: [email protected], Web: www.berkeleynucleonics.com

5.14

[SOURce]:FM Subsystem (Frequency Modulation)

8

Command

Parameters

Unit (default)

[SOURce:]FM:DEViation

<value>

1000 Hz

[SOURce:]FM:SENSitivity

<value>

1000 Hz/V

[SOURce:]FM:INT:FREQuency

<value>

400 Hz

[SOURce:]FM:INTernal:SHAPe

RD|RU|SINE|SQUare|TRIangle

SINE

[SOURce:]FM:SOURce

INTernal | EXTernal

EXT

[SOURce:]FM:STATe

ON|OFF|1|0

OFF

[SOURce:]FM:COUPling

DC | AC

AC

:FM:DEViation

[SOURce]:FM:SENSitivity <value>

[SOURce]:FM: SENSitivity?

This command sets the frequency modulation deviation. This setting will be used if :FM:SOURce is set

to LFGenerator.

The variable <value> is expressed in units of Hertz.

*RST 1000

:FM:SENSitivity

[SOURce]:FM:SENSitivity <value>

[SOURce]:FM: SENSitivity?

This command sets the frequency modulation deviation per one volt peak amplitude signal input. This

setting will be used if :FM:SOURce is set to EXTernal.

The variable <value> is expressed in units of Hertz per Volt.

*RST 1000

:FM:INT:FREQuency

[SOURce]:FM:INT:FREQuency <value>

[SOURce]:FM:INT:FREQuency?

This command sets the frequency modulation rate in Hz. This setting will be used if :FM:SOURce is

set to INTernal.

The variable <value> is expressed in Hertz.

*RST 400

:FM:INT:SHAPe

[SOURce]:FM:INT:SHAPe RD|RU|SINE|SQUare|TRIangle

[SOURce]:FM:INT:SHAPe?

This command specifies the FM modulation shape. RD selects Ramp-Down and RU ramp up.

Standard waveforms available are SINE, SQUare and TRIangle.

Advertising
This manual is related to the following products: