SECTION 4 - BOOM & PLATFORM

3120740

– JLG Lift –

4-53

i. When viewing the above display, press

"ENTER"

. The screen will display the fol-

lowing:

j. Lower the tower boom onto the boom stop.

Continue to hold the tower boom down function
for at least twenty (20) seconds WITHOUT
RELEASING THE FUNCTION SWITCH
. The
calibration must recognize continuous activation
of the tower down function switch for the
required time.

After the required activation time has passed,
r e l e a s e t h e f u n c t i o n s wi t c h a n d p r e s s

"ENTER"

. The analyzer will display the fol-

lowing message:

If the calibration has been completed success-
fully, the screen will automatically change to: