SECTION 6 - JLG CONTROL SYSTEM (S/N 0300065534 TO PRESENT)
6-38
– JLG Lift –
3120740
20
PLATFORM
ALARM
0=NO
1=FAULT CODE
Displays/adjusts
platform alarm
presence/functions
0
1
Sounds Continuously When
Above Elevation And Tilted
Only.
Sounds Continuously When
Above Elevation And Tilted,
And In Conjunction With Fault
Code Flashes. (Option)
1
0
21
Tower Prox
Switches
0=NO
1=YES
Displays presence/
function of Tower
Proximity switches
for the models
specified.
0
1
No Tower Prox Switches
Installed
Tower Prox Switches
Installed
1
0
Table 6-5. Machine Configuration Parameters