SECTION 6 - JLG CONTROL SYSTEM (S/N 0300065534 TO PRESENT)
3120740
– JLG Lift –
6-41
BASKET ROTATE
ACCELeration
0.1 to 5.0
1.8
DECELeration
0.1 to 3.0
0.3
MlNimum LEFT speed
0 to 65
34
MAXimum LEFT speed
0 to 100
50
MINimum RIGHT speed
0 to 65
34
MAXimum RIGHT speed
0 to 100
50
Engine RPM
800 to 2900
1500
JIB
Lift ACCELeration
0.1 to 5.0
5.0
Lift DECELeration
0.1 to 3.0
1.0
MINimum UP speed
0 to 65
46
MAXimum UP speed
0 to 100
52
MINimum DOWN speed
0 to 65
45
Engine RPM
800 to 2900
1800
STEER
MAXimum speed
0 to 100
100
Engine RPM
800 to 2900
1800
GROUND MODE
Tower LIFT UP speed
0 to 100
100
Tower LIFT DOWN speed
0 to 100
100
Upper LIFT UP speed
0 to 100
60
Upper LIFT DOWN speed
0 to 100
60
SWING speed
0 to 100
60
Upper TELEscope speed
0 to 100
70
Tower TELEscope speed
0 to 100
100
BASKET ROTATE speed
0 to 100
50
BASKET LEVEL speed
0 to 100
50
JIB LIFT speed
0 to 100
50
JIB Swing
0 to 100
N/A
4150365-3
Table 6-6. Personality Ranges/Defaults
FUNCTION
PERSONALITY
RANGE
DEFAULTS