9 machine personality settings, Machine personality settings -39, Personality ranges/defaults -39 – JLG 800A_AJ ANSI Service Manual User Manual

Page 369

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM (S/N 0300065534 TO PRESENT)

3120740

– JLG Lift –

6-39

6.9 MACHINE PERSONALITY SETTINGS

NOTE: Personality settings can be adjusted within the

adjustment range in order to achieve optimum
machine performance.

Table 6-6. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS

DRIVE

ACCELeration

0.1 to 5.0s

2.0

DECELeration

0.1 to 3.0s

2.0

FORward MINimum speed

0 to 25%

4

FORward MAXimum speed

0 to 100%

30

REVerse MINimum speed

0 to 35%

4

REVerse MAXimum speed

0 to 100%

30

ELEVATED MAXimum speed

0 to 50%

15

CREEP MAXimum speed

0 to 45%

20

Engine RPM

800 to 2900

1800

TOWER LIFT

ACCELeration

0.1 to 5.0s

1.5

DECELeration

0.1 to 3.0

0.5

MlNimum UP speed

0 to 60%

39

MAXimum UP speed

0 to 100

100

MINimum DOWN speed

0 to 60

38

MAXimum DOWN speed

0 to 100

100

Engine RPM

800 to 2900

1800

UPPER LIFT

ACCELeration

0.1 to 5.0

2.5

DECELeration

0.1 to 3.0

0.7

MlNimum UP speed

0 to 60%

30

MAXimum UP speed

0 to 100

67

CREEP Maximum UP speed

0 to 65

55

MINimum DOWN speed

0 to 60

45

MAXimum DOWN speed

0 to 100

76

CREEP maximum DOWN speed

0 to 75

55

Engine RPM

800 to 2900

1800

Advertising