Flash code 6/6 indicates problems with the CAN bus.

10

CAN BUS FAILURE:

The ground module or platform module is not receiving. This is prob-
ably due to wiring problems between the platform and ground mod-
ules.

7/7

Flash code 7/7 indicates problems with a motor.
NOT REQUIRED

8/1

Flash codes 8/1 indicate sensor issues.

11

UMS SENSOR NOT CALI-
BRATED

The control system detects a sensor out of range condition or a not
calibrated fault with the UMS angle sensor

UMS SENSOR FAULTED

The system detects that the UMS sensor frequency outside the
100Hz +/- 5Hz range or the duty cycle is outside 50% +/- 21%
range

TOWER LIFT DOWN OUTPUT
SHORT TO GROUND OR OPEN
CIRCUIT

Short to Ground or open circuit has been detected on the Tower Lift
Down output.

TOWER LIFT DOWN OUTPUT
SHORT TO BATTERY

Short to battery has been detected on the Tower Lift Down output

PLATFORM INDICATOR OUTPUT
SHORT TO GROUND OR OPEN
CIRCUIT

Short to Ground or open circuit has been detected on the Platform
Indicator output

PLATFORM INDICATOR OUTPUT
SHORT TO BATTERY

Short to battery has been detected on the Platform Indicator output

GROUND INDICATOR OUTPUT
SHORT TO GROUND OR OPEN
CIRCUIT

Short to Ground or open circuit has been detected on the Ground
Indicator output

GROUND INDICATOR OUTPUT
SHORT TO BATTERY

Short to battery has been detected on the Ground Indicator Output

11

TURNTABLE SENSOR NOT CAL-
IBRATED

The control system detects that the Chassis Tilt sensor is not cali-
brated or there is an internal fault with the sensor

TURNTABLE FAULTED

The system detects that the Chassis tilt sensor frequency outside the
100Hz +/- 5Hz range or the duty cycle is outside 50% +/- 21%
range the control

9/9

Flash code 9/9 indicates problems with the controller or memory issues.

11

PLATFORM MODULE FAILURE:
hwfs CODE 1

Platform module V(Low) FET has failed

GROUND MODULE FAILURE:
hwfs CODE 1

Ground module V(Low) FET has failed

EEPROM FAILURE – CHECK ALL
SETTINGS

A critical failure occurred with the EEPROM

12

Table 6-7. Help Fault Codes, Displayed Faults, and Descriptions - Prior to S/N 0300066931