13 sauer piston pump s/n 0300121643 to present, Sauer piston pump s/n 0300121643 to present -42, Gauge port locations -42 – JLG 800A_AJ ANSI Service Manual User Manual

Page 322: Symbols used -42, Gauge and port information -42

Advertising
background image

SECTION 5 - HYDRAULICS

5-42

– JLG Lift –

3120740

5.13 SAUER PISTON PUMP S/N 0300121643

TO PRESENT

Table 5-3. Symbols Used

Symbol

Meaning

Symbol

Meaning

Non-reusable part, use a
new part

Inspect for wear or dam-
age

Option - either part may
exist

Note correct orientation

Internal hex head

Torque specification

O-ring boss port

Pull out with tool - press fit

Lubricate with hydraulic
fluid

Cover splines with instal-
lation sleeve

Apply grease /petroleum
jelly

Pressure measurement /
gauge location or specifi-
cation

The symbols above can be found in the pump illustrations. The legend
above is provided to define each symbol and explain its purpose.

Inlet port S
SAE J1926/1,

1.875-12

System gauge po

SAE J1926/1,

0.4375-20

Case drain po

rt L1

SAE J1926/1,

0.875-14

Outlet port B

SAE J1926/1,

1.3125-12

Case drain port L2
SAE J1926/1,

0.875-14

rt M2

Table 5-4. Gauge and Port Information

Port

Purpose

Range of Pump

Fitting

M2

System pressure

0-5000 psi [0-300 bar]

7/16 - 20 o-ring fitting

M4

Servo pressure

0-5000 psi [0-300 bar]

7/16 - 20 o-ring fitting

L1,L2

Case pressure

0-100 psi [0-10 bar]

7/8 - 14 o-ring fitting

X1

Load Sense signal

0-5000 psi [0-300 bar]

7/16 - 20 o-ring fitting (tee into Load Sense signal line)

Figure 5-34. Gauge Port Locations

Advertising