8.3. Parameter Tables
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if available) for programming via a
telephone line, description of EasyGate UMTS Data's behavior, setting options, setting
step and default (initialization) value.
8.3.1. Telephone Line Parameters
8.3.1.1 Dialing parameters
Type of dialing
Function No.:
-
Select the dialing type to be received by EasyGate from the PBX or telephone
set. EasyGate accepts only the selected type of dialing, ignoring the others.
Setting options:
DTMF
-EasyGate receives tone dialing only.
Pulse
-EasyGate receives pulse dialing only
Default setting: DTMF
Time to dial [s]
Function No.:
-
Timeout during which EasyGate waits for further digits to be dialed. It starts to
establish connection when this timeout passes.
Setting options: 1-15 s
Setting step:
1 s
Default setting: 5 s
Minimal On Hook [ms]
Function No.:
-
The minimum line current discontinuation that EasyGate evaluates as hang-up.
Setting options: 100-1500 ms
Setting step:
100 ms
Default setting: 500 ms
Beep after dialing end
Function No.:
-
Select a beep to signal the end of dialing (beginning of outgoing call
establishing).
Setting options: YES/NO
Default setting: YES
8.3.1.2 Signaling
Line reversal indication for call in progress
Function No.:
-
Select call in progress signaling by telephone line polarity reversal. There is
voltage of reversed polarity on the telephone line during the whole call.
Setting options: YES/NO
Default setting: NO
Tariff pulse when call starts/ends
Function No.:
-
Signaling of call start or end by tariff pulse.
Setting options: