Acoustic Signalling and Keypad Configuration

3.1

47

$HeliosId$

2N

®

Helios IP identifier

Miscellaneous subsection.

Internal application launched
after turning on or restarting of 2N

®

Helios IP, the internal

application of 2N

®

Helios IP is launched. A successful launch is

signalled by this tone combination.

Connected to LAN, IP address received
after the launch of the internal application 2N

®

Helios IP logs into

the LAN. A successful login is signalled by this tone combination.

Disconnected from LAN, IP address lost
whenever the UTP cable is disconnected from 2N

®

Helios IP, this

status is signalled by this tone combination.

Invalid telephone number or invalid unlocking code
you can dial an extension telephone number or enter the door-
opening code using the keypad. An invalid code is signalled by
this tone sequence.

Switching to default network parameters
after power up, a 30-second timeout is set for entering the
resetting code. For switching to default network parameters refer
to the Switching to Default Network Parameters – Static IP
Address
and Switching to Default Network Parameters – Dynamic
IP Address
subsections.

Call end signalling
a time limit can be set after which your call will be terminated. To
prolong a call, push a VoIP telephone key. The time limit is set
due to protection against call blocking.

Connected call for VoIP phone-to-2N

®

Helios IP calling

a short tone is played to signal call connection.

Table 3.1 List of Tone Signals

Switching to Default Network Parameters

– Static IP

Address

Switching to the default network parameters with the static IP address can be
performed in two ways. Either through a web interface as described in the Network
subsection or by pushing a combination of the quick dialling buttons as shown in
Figures 3.1–3.3. Upon resetting, the web server is automatically switched on if
switched-off before. The buttons have to be entered within 30 seconds after the
internal application launch as signalled by the

tone sequence. The maximum

delay between the buttons is 2 s.