2N EasyGate - User Manual User Manual

Page 24

Advertising
background image

19

8.3. Parameter Tables

All programmable parameters are listed in this section. Each parameter is

accompanied with the unit used, function number (if available) for programming via a
telephone line, description of EasyGate's behavior, setting options, setting step and
default (initialization) value.

8.3.1. Telephone Line Parameters


Type of dialing

Function No.:

-

Select the dialing type to be received by EasyGate from the PBX or telephone
set. EasyGate accepts only the selected type of dialing, ignoring the others.
Setting options:

DTMF

-EasyGate receives tone dialing only.

Pulse

-EasyGate receives pulse dialing only

Default setting: DTMF


Time to dial [s]

Function No.:

-

Timeout during which EasyGate waits for further digits to be dialed. It starts to
establish connection when this timeout passes.

Setting options: 1-15 s
Setting step:

1 s

Default setting: 5 s


Dial tone

Function No.:

-

This tone is generated after Off-Hook in case EasyGate is ready to accept
dialing.

Setting options:

Continuous -EasyGate generates continuous dial tone.

Interrupted -EasyGate generates interrupted tone with 320/640 ms timing.

Default setting: Continuous


Tone after disconnection

Function No.:

-

If the remote subscriber hangs up first, the EasyGate subscriber can hear the
tone selected here.

Setting options:

Busy

-EasyGate transmits the busy tone upon call end.

Permanent -EasyGate transmits the permanent tone upon call end.

Default setting: Busy tone


Minimal On Hook [ms]

Function No.:

-

The minimum line current discontinuation that EasyGate evaluates as hang-up.
Setting options: 100-1500 ms
Setting step:

100 ms

Default setting: 500 ms